Stainless Steel Hex Head Composite Panel to Light Section 

For fixing insulation panels to cold rolled purlins (1.2mm – 3.5mm steel).


      

These items are UKCA and CE approved.

Part Number Length (MM) Diameter (MM) Drill Point Min Panel Thickness (MM) Max Panel Thickness (MM)
HT65.2SS 65 5.5 No. 2 25 45
HT85.2SS 85 5.5 No. 2 35 60
HT110.2SS 110 5.5 No. 2 55 85
HT125.2SS 125 5.5 No. 2 60 100
HT125.2SS(A4) 125 5.5 No. 2 60 100
HT145.2SS 145 5.5 No. 2 65 120
HT145.2SS(A4) 145 5.5 No. 2 65 120
HT175.2SS 175 5.5 No. 2 95 150
HT175.2SS(A4) 175 5.5 No. 2 95 150
HT200.2SS 200 5.5 No. 2 120 180
HT220.2SS 220 5.5 No. 2 135 190
HT250.5SS 250 5.5 No. 2 175 230
HT300.2SS 300 5.5 No. 2 210 275

Light section screws fasten composite panels to cold rolled purlins (1.2mm – 3.5mm steel).

  • Stainless steel provides excellent corrosion-resistance which increases the life-span of the fixing.
  • Hex heads are standard across the industry, and require a 5/16″ socket, which we also supply.
  • The coarse thread provides excellent engagement with the purlin, maximising pull-out values.
  • The high thread has a wider diameter than the lower thread, so that the outer sheet is well-engaged.
  • The no. 2 drill point is designed to maximise accuracy whilst ensuring a clean cut through up to 3.5mm steel, without burn-out.

For maximum fastener performance, we recommend using a tek screw driver which does not exceed 2500RPM.

 

 

 

 

 

 